Powder coating service has become a very reliable process for aluminium facades. It includes three processes: First, a documented pretreatment and coating process. Second, measurement of the film thickness, and third, a warranty that states the standard it follows. The facade of the building can only look perfect on the day of handover and still flake off after a few monsoons if even a single step or element is skipped. To prevent any failures at the process level, let’s begin a study that you should take seriously.
The first stage is done at the surface level, and just after that, the powder coating process gets started.
The raw extrusions have so much oil, dust, and oxide coating. The aluminium profiles are then cleaned, and undergoes with cleamical processes. After that, the surface gets smooth when you lift up at the edges. Once this process is done, the powder coating takes centre stage.
After the chemical treatment, the electrostatic powder is sprayed, to which it clings, then baked. According to a recent study, this profile can be baked for only 19-20 minutes at a temperature of 190°C. Even though the temperature stated is metal temperature, but thickness and thinness may vary and have their own level of timing. And for thicker sections, the metal temperature is required. After this process, the film is measured and brought to the required thickness.
The thickness process is the only process that differentiates its specifications from others, and most quotes are compared unfairly. The following are the minimum dry film values:
One thing you must note is that Qualicoat minimum requires about twice the AAMA figure. The Interpon data suggests that around 60-80 microns are required. So, a specification stating that 1.2 mils are required is not similar to asking for 60 microns. Speaking of which, a statement must state the coating standard along with its measurement unit.
The thickness can be measured at multiple points. Generally, the internal corners and pockets will show less thickness than flat areas. Try to request the specific results from the applicator. This will help you know the quantity of film on the metal and the performance of the same in an outdoor environment.
Two systems dominate facade specifications, and each sets a different bar for the warranty that follows.
AAMA 2604 and 2605 are US standards for architectural coatings. Amico Architectural says that it can endure 3000 and 4000 hours, respectively, in salt fog testing. They both also maintain at least 30% and 50% gloss levels. Qualicoat categorises finishes into 3 classes depending on their weathering properties. However, you should know that India’s powder coating standard (IS 13871) applies only to mild steel. Therefore, the majority of building facades follow either of the aforementioned standards. Again, the warranty is a separate entity from the standard.
The Qualicoat will never set the warranty periods, but the applicator does. Amico gives the usual 2604 warranties of between 10 and 20 years, 2605 of 20 to 30, and Interpons? It gives the warranty of up to 30 years for D3020, when handled by a Qualicoat-approved applicator. The markings stated above are the American and manufacturer averages; the Indian period times may vary. Also, look out the defects that are covered, say fadind, chalking or peeling and what the exclusions it includes, like cleaning neglect, or coastal locations. Also, check who is going to handle the claim.
Your strong warranty correlates with the brand you are hiring. So, you must know what the right company should have and how you can choose.
There are multiple powder coating brands who offers the top notch grade, but still you must consider the powder’s Qualicoat or AAMA Certification number that’s used on your project. You need to ensure that the applicator has permission to use that particular powder because some warranties won’t apply unless your applicator has approval. As you consider that, let’s prepare a quality checklist you must ensure while hiring a powder coating company.
When you are hiring a powder coating company, you need to ensure:
As a right brand, you can consider Aparna Externa for your powder coating service, as they have the complete list for the same and also serve curtain walls, window doors, glazing, aluminium cladding, and more.
A right facade finish has three segments in a row: a documented pretreatment line, a film thickness, and a stamped or signed warranty. You must ensure all the above-mentioned items are in place to ensure a smooth process and your expected result. You can also contact the Aparna Externa team to get the detailed process of how a powder coating service can be completed.
Ans: The standard thickness depends on the specification name. But Qualicoat has already set a minimum of 60µm for classes 1 and 2, and 50µm for class 3.
Ans: They both are the American performance standards for Powder Coating. The 2605 is stricter and requires 4,000 hours of salt sprays meanwhile AAMA 2604 requires 3000.
Ans: The warranty is given by the powder manufacturer.